Unofficial Content

Warning: The .NET Mobile generator has been discontinued. Refer to Native Mobile Applications Development.

Problemas Comunes

 

Error creating data base: Error loading data store 'C:\Documents and Settings\All Users\Application Data\Microsoft\VisualStudio\devices\7.1\conman_ds'

 
Compiling Reorganization...
gxexec
"C:\Modelos\ModelYi\Prueba\DATA002\bldReorganization.cs" -r:GxBaseBuilder.dll
-arg:csc="C:\WINDOWS\Microsoft.NET\Framework\v1.1.4322\csc.exe" /noconfig
@cf_csc.rsp -arg:mdlpath="C:\Modelos\ModelYi\Prueba\DATA002\"
Building bin\Reorganization.dll
Versión del compilador de Microsoft (R) Visual C# .NET7.10.6001.4 para
Microsoft (R) .NET Framework versión 1.1.4322
(C) Microsoft Microsoft Corporation 2001-2002. Reservados todos los
derechos.

Compilation Successful

Executing Reorganization...
C:\Modelos\ModelYi\Prueba\DATA002\bin\Gxcff5.exe
"C:\Modelos\ModelYi\Prueba\DATA002\bin\reor.inf"
"C:\Modelos\ModelYi\Prueba\DATA002\bin" "reor"
Error loading data store 'C:\Documents and Settings\All Users\Application
Data\Microsoft\VisualStudio\devices\7.1\conman_ds'
Reorganization not completed.
Execution Failed


Este error se debe a que el Visual Studio está en un lenguaje distinto a ingles, mientras que el emulador está en ese idioma.
La solución es buscar todas las sub-carpetas correspondiente al idioma de C:\Documents and Settings\All Users\Application Data\Microsoft\visualstudio y remplazarlas (1034 en caso de español) y copiarlas con el nombre 1033 que se corresponde a Ingles.

 