Table of contents
Official Content

Live Editing is an important functionality that allows you to modify different parts of the design and behavior of a Web or Native Mobile app with no need to generate or compile anything, or to save those changes.

To do this, the application is connected to the IDE in a way that allows for communication between them (the changes’ impact). In this article, you will find how this connection is established, and some tips to help you in case of any problems with it.

General behavior of the connection

To simplify the understanding of this article, two terms are defined below:

Server- it’s the PC where GeneXus is being executed (the IDE).

Client- it’s where the application is being executed. It can be the computer where the Web application is executed (a web server, in the cloud, or the PC itself) or the device (Android or Apple) where the application is executed (even using the [Knowledge Base Navigator]).

The basic behavior is that the Client is connected to the Server using TCP/IP, so both must be in the same network.

How can I know if there’s a Client connected to the Server?

In the IDE’s output, a message is displayed, similar to “Live Editing Client accepted:Device_Name”

Likewise, the Live Editing window shows the connected Clients. In the following image, you can see that there is a Web application and a Native Mobile application connected to the Server, as well as information referring to those Clients (computer, theme, etc.).

Live Editing Clients Connected

Also, in the Client a message will appear, indicating that the connection to the Server was successful. The message, whether on a Web app, an Apple app, or an Android app, will be “Connected to LivePreview at xx.xx.xx.xx on port 30100”.

FAQ

How to fix the lack of functionality in live editing and live inspector when running the trial version of GeneXus in standard mode?

Run GeneXus as an administrator. This will allow the proper functioning of the live editing and live inspector while running the trial version in standard mode.

What IP/Port is used for the connection?

When the “Live editing” mode is executed, all the IPs where the Server is listening are detected; that is to say, all the ones where the Client could establish the connection. Those directions are also included in the “settings.json” file. This file is included in the app, and therefore the IPs/Ports that will be used in the Client to connect to the Server will be included as well.

i2016-07-21_14591_png

If you are executing on the Web, this information is generated in the GXCFG.JS.

At port level, the port 30100 is used, and if that one is already in use, the port 30101 is used, and so on until the port 30150. This “poll” is to avoid executing the application once again after closing and opening the IDE (the port can change). If the Server listens in any of the IPs/Ports previously mentioned, the connection will be established.

What happens if there are changes in the network?

When the change is detected, the message “Network has changed. You may need to regenerate the main object to use Live Editing” is displayed in the IDE.

If the client can still connect from one of the IPs/Ports then nothing is required. If the connection cannot be established, you must execute the application again from the IDE, so that the list of IPs in the Client is updated.

What happens if you have more than one instance of GeneXus running on the same PC?

To be precise, for the connection between the Server and the Client, the KB’s GUID is used besides the IP/Port. Therefore, when the Client wants to establish the connection, if the IP/Port to which it connects is being used by another KB, it tries to connect to another port.

If a Client (app) tries to connect to a Server (IDE) but the app does not match the KB, the following message will be displayed in the IDE:

Live Editing Client rejected:'Device_Name'
Reason: Knowledge Base mismatch:(KB_Name)

Troubleshooting

The connection between the Client and the Server (Live Editing) does not work

The only requirement for the connection to work is that the Client and the Server must be in the same TCP/IP newtwork; therefore, first you should verify that this is the case. There are many ways to do this; for example: if you have an HTTP server in the Server (in the PC where GeneXus is executed you have IIS or Tomcat) you can test the HTTP connection.

Testing the connection using HTTP

Try to connect from a browser in the Client using the IPs shown in the IDE and the port being used (default for IIS is 80 and for Tomcat 8080).

IMG_09442_jpg

If you CAN’T successfully access the application server, Live Editing will not work either. Contact your Network Administrator to check for connectivity.

Testing the HTTP to Live Editing connection

If the HTTP connection Works, then the next step is to try with the port shown in the IDE:

i2016-11-16_1707_png

To check that the connection can be established successfully using the correct port, the URL you should use is “IP:Port/live/". If the port is not blocked, the device’s browser will show an answer similar to the following:

IMG_09421_PNG

Note: This answer can be seen if the Server is Windows 10; in Windows 7, the browser’s answer is simply a blank screen.

If the port is NOT accessible, a screen similar to the one shown below will appear.

IMG_0946_PNG

Note: in Windows 7 the connection might just be “frozen”.

If this happens, it means that the port is blocked (or closed). It’s convenient to disable your Firewall and turn off your antivirus to be able to identify what is making it inaccessible. Then, in any of the options, you should be able to configure the “rules” so that the port is not closed.

The connection from HTTP to the Live Editing works but from the Client (app) it doesn’t

If you can access the “IP/Port/live” from the Client’s browser but the Client (app) still doesn’t connect to GeneXus’ IDE, then you should proceed to investigate deeper to identify the cause of the problem (not being able to connect).

Make sure the server is listening to the IDE’s port. For this you can run the following command: netstat -ta

There, look for the port:

image1_jpg

If the port is not shown, it means that it’s being blocked.

You can try to execute the application once again, to make sure that the settings.json file, which was mentioned earlier, is up to date. You can also verify that this file contains an entry with the name IDE_ConnectionString, where you can see the same IPs as the ones shown in the IDE.

Even though the Live Editing is turned off, the following message is still shown: Connected to LivePreview at xx.xx.xx.xx on port NNNN

Problem

Live Editing was used on the web but later turned off (changing to “release” mode), but at runtime the message “Connected to LivePreview at xx.xx.xx.xx on port 30100” is still shown.

Solution:

Live Editing on the web is implemented through a JS (GXCFG.JS). The problem is that the JS can be cached in the browser. You can delete the cache or open an incognito window to check if this is the problem.

Even if you want to use Live Inspector, the IDE doesn't show a connection in the IDE LiveEditing tab.

Problem:
You cannot see a connection in the IDE.

Solution:
Make sure there is a network connection, do a Rebuild all, and reboot the machine. Somehow it was detected that the machine's network environment (it had no internet connection) had problems. Also, somehow the port number has changed. To solve changing the port number, you will need to reboot the machine.

Last update: February 2024 | © GeneXus. All rights reserved. GeneXus Powered by Globant